● FEATURES
Heavy duty flexible round cable; 1 core, specially designed for secondary connection from welding machine to electrode holder.

 

Standards Conforming to international standards UNE 21027-6 (rubber insulated cables for rated voltage of 450 / 750 V AC); IEC 60332-1 (flame retardancy); IEC 60332-3 (reduced flame propagation).
Working voltage Uo/U: 450 / 750 V AC.
Test voltage 2.5 KV AC during 5 minutes.
Temperature range

-60º C / +135º C.

 

 

● CONSTRUCTION
Conductor
High purity electrolytic soft annealed flexible copper conductor stranded in successive layers in opposite directions; IRAM 2011, IRAM 280/IEC 60228.
Sheath
• Heavy duty FR elastomeric compound.
• Flexible PVC oil & water resistant.
Flexibility
Minimum bending radius: 4 mm x O.D.
Optional
Sequential meter marking.
 
Identification
Packaging
Available in coils or wooden drums.
Applications
Wiring flexible connections.
Note: overall dimensions are approximate and subject to change without notice.

Description

Ø
wire

 

mm

Nº of strands Nº of
wires
Total Nº
of wires

Cross section

mm2

Maximun

conductor

resistance

at 20ºC

Current
carrying

capacity

a 40ºC

Sheath

Nominal thickness

mm

Outer

Ø
mm

Welding cable 1x10/0,20/2,0 0,20 7 43 301 10 1.91 115 A 2.0 8.52
Welding cable 1x16/0,20/2,0 0,20 19 25 475 16 1.21 145 A 2.0 9.75
Welding cable 1x25/0,20/2,0 0,20 19 39 741 25 0.780 195 A 2.0 11.18
Welding cable 1x35/0,20/2,0

0,20

19 54 1026 35 0.554 245 A 2.0 12.45
Welding cable 1x50/0,30/2,0 0,30 19 35 665 50 0.386 310 A 2.0 14.21
Welding cable 1x70/0,30/2,0

0,30

19 49 931 70 0.272 385 A 2.0 16.08
Welding cable 1x95/0,30/2,2 0,30 19 65 1235 95 0.206 470 A 2.2 18.31
Welding cable 1x120/0,30/2,2

0,30

37 43 1591 120 0.161 540 A 2.2 20.24
Welding cable 1x150/0,30/2,4 0,30 37 53 1961 150 0.129 620 A 2.4 22.38